PEMFC MEA
Introduction & Application |
|
| |
|
|
| |
Product Outlines
Proton Exchange Membrane Fuel Cell Membrane Electrode
Assembly (PEMFC MEA) ,the most important component for direct hydrogen or
reformate hydrogen fuel cell, consists of anode and cathode catalyst on both
sides of proton exchange membrane, generating electric power through the
electrochemical reaction occurred on anode and cathode.
|
 |
|
PEMFC
MEA3
|
 |
|
PEMFC
Bordered MEA
|
|
 |
Product Feature
Product
Specification
|
Item
|
Product Spec.
|
MEA3 |
Bordered
MEA
|
Edge-seal
MEA |
| 1 |
Proton exchange
membrane |
Nafion®211,
Nafion®212 or Nafion®
XL , Nafion®-HP
|
| 2 |
Catalyst metal |
Anode : Pt or; Cathode: |
| 3 |
Gas diffusion
layer (GDL)
|
N.A. |
Customized
design
|
| 4 |
Anode type |
Pure hydrogen or reformate
hydrogen
|
| 5 |
MEA size |
Customized design
|
| 6 |
MEA performance* |
≧0.6V@1000mA/cm2 |
| 7 |
MEA quality
inspection
|
1. Visual
inspection
2. Thickness
measurement
3. Leakage
test
|
*Note:Test condition of MEA3 and GDL
MEA3
(Nafion®211) and
GDL
test condition |
| Single
cell temperature |
65℃ |
| H2
flow rate |
1.25X |
| Air
flow rate |
1.67X |
| RH |
100% |
PEMFC MEA I-V Curve
Test (Nafion®211)
|

|
| Test
condition |
| Single cell
temperature |
65℃ |
| H2 flow
ratio |
1.25X |
| Air
flow rate |
1.67X |
| RH
|
100% |
| Test result |
MEA
performance≧0.6V@1000mA/cm2
|
|
Reformate PEMFC MEA I-V
Curve Test (Nafion®211)
|

|
| Test
condition |
| Single cell
temperature |
65℃ |
| H2 flow
ratio |
1.25X |
| Air
flow rate |
1.67X |
| RH |
100% |
| Test result |
≧0.6V@1000mA/cm2
(Test by pure hydrogen) |
|
Nafion®211、Nafion®-XL
and Nafion®-HP
comparison
| Item
|
Comparison
|
Nafion®-211 |
Nafion®-XL
|
Nafion®-HP |
| 1 |
Thickness |
25 um |
27.5 um |
20 um |
| 2 |
Hydrogen
Crossover (ml/min.cm2) |
< 0.02 |
< 0.015 |
< 0.015 |
| 3 |
Conductivity
(23℃,100%RH) |
N.A. |
> 72 (in plane)
> 50.5 (through plane)
|
> 72 (in plane)
> 50.5 (through plane) (higher conductivity with 25%RH,80℃)
|
| 4 |
Accelerated
durability test- Method 1 (Load Cycling Accelerated Durability Test) |
300 Hrs |
>4,800 Hrs |
>4,800 Hrs |
| 5 |
Accelerated
durability test- Method 2 (OCV Accelerated Durability Test) |
3umole
F- /cm2-hr |
< 0.1umole
F-/cm2-hr |
< 0.1umole
F- /cm2-hr |
| 6 |
Available
humidity range |
100%RH |
> 50%RH |
> 20%RH
|
Product Applications
PEMFC MEA︰
Applied to hydrogen fuel cell in terms of pure hydrogen as anode fuel.
Reformate PEMFC MEA︰
Applied to hydrogen fuel cell in terms of reformate hydrogen as anode fuel.
|
|
|
| |
Update Date:
2013/4/1 |
|
|